125 Amp Panel Max Load
He had a 200 amp panel presumably with other loads on that panel feeding a 100 amp panel with other loads on that panel feeding a 100 amp panel.
125 amp panel max load. The panel rating the panel is rated to support 125 amperes when connected to a 120 240 volt 3 wire system. For example if the load calculation comes out to 48 amps you should use a 50 amp breaker to protect the circuit. Often the result is not a common circuit breaker size. Feeder circuits supplying subpanels are 240 volt and require a double pole circuit breaker.
To convert watts into the actual connected load as amps the formula is. The load will be shown as watts on the nameplate label of the ev charger. Since the standard recommendation is for the load to total no more than 80 percent of the capacity this means that the 20 amp circuit has a realistic capacity of 1920 watts. Hi all need some help checking my thinking i can t find my formulas.
The likely maximum load on that circuit could reach 1 800 watts putting it right at the maximum that a 15 amp circuit providing 1 800 watts could handle. The total may be more than twice the total amperage of the box. 1965 house with basement sub panel breakers total 180 amps 4 15 amp 120 volt 2 50 amp 240 volt 1 20 amp 240 volt 180 amps 180 amps x 75 135 amps panel is rated for 125 amps max. For example a 20 amp 120 volt branch circuit has a total capacity of 2 400 watts 20 amps x 120 volts.
Add the amperages of all the individual breakers in the box. Did i do math correct to say panel is overloaded. The inspector will most likely want to see load information for the electrical service panel. And you can simply round up to the next higher size of the breaker.
But if you put a single 100 watt lightbulb in the bathroom light fixture you create a situation where a tripped circuit breaker is likely. If an appliance attached to a 120v energy source requires 1200 watts to run it will automatically pull 10 amps of current through the line. For example a 100 amp service panel may have circuit breakers that add up to more than 200 amps. This means that 125 amperes can flow through each of the upper bus bars and each main lug without anything melting or catching fire.
If the most downstream 100 amp panel is to be used to it maximum then nothing could be used in the intermediate 100 amp panel as the breaker protecting that intermediate 100 amp panel would trip. When it comes to designing a circuit breaker panel you must understand how the appliances pull current.